SecOps SignalSecurity Intelligence Workspace
Collection Degraded30 / 46 Sources HealthyPublic Intel Only
Vulnerabilities/CVE-2024-52051Public Intelligence Dossier
Source: Source type: NVD · Limited verification•Last verified: •Collection Degraded
CVE-2024-52051Unknown / EvaluatingHIGH (raw)CVSS 7.3CWE-20

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1)

Published: 10 Dec 2024•Last updated: 13 Oct 2026, 03:47 PM IST•Source identifier: productcert@siemens.com
Dossier completeness: source-provided sections 1 / 3 · rule guidance available. Missing source facts count as incomplete.
Official source
CISA KEV catalog
Unknown
KEV status was not determined.
CVSS score
7.3HIGH (raw)
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Metric sourceproductcert@siemens.com
EPSS probability
0.2%0.002
Percentile7th
Weakness type
CWE-20
No further CWE recorded
Remediation
Patch status unknown
No fixed version or KB recorded

Why It Matters

Analysis dossier

Why It Matters

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.

SOC priority

High

Actively exploited

Unknown

Publicly disclosed

Unknown

Risk basis: SOC ecosystem technology relevance; HIGH severity; No confirmed exploitation signal in current enrichment

Affected Products & Remediation

0 source-backed products
Affected products and versions (source)Not provided by source
Recorded patch / KBNot provided by source

Vendor or catalog guidance (source)

Not provided by source

Known exploitation (source facts)

Only what a source states. Unknown means no source has said either way; it is not "not exploited".

CISA KEV
Unknown
Exploited (source statement)
Unknown
Publicly disclosed (source)
Unknown

Suggested hunting (rule-based inference)

SecOps Signal recommendation (rule-based inference). These steps are hunting hypotheses from the vulnerability class; they do not state or imply that exploitation occurred here or anywhere.

Matched local-privilege-escalation (CVSS AV:L, CVSS PR:L)

Exposure

  1. Identify hosts reporting this CVE, prioritising shared or multi-user systems.Telemetry: DeviceTvmSoftwareVulnerabilities · A local, low-privilege vector matters most where untrusted users can run code. · Rule local-privilege-escalation

Exploitation evidence

  1. Look for low-privileged processes spawning SYSTEM or root-level child processes on affected hosts.Telemetry: DeviceProcessEvents · Hunting hypothesis from the CVSS vector; privilege transitions are a focused starting point, not evidence of attack. · Rule local-privilege-escalation

Response

  1. Confirm the source-stated update on affected hosts.Telemetry: DeviceTvmSoftwareVulnerabilities · Host inventory can verify remediation. · Rule local-privilege-escalation

CISA KEV Record

CISA KEV status was not determined for this record.

Change History & Source Data

— No recorded material change

CNA / source
productcert@siemens.com
Record status · verification
UPDATED · NVD API
CPE
Unknown
Detection Hunting Query

— No published hunting query names this record. Browse community and library queries instead.

Correlated briefings

— No published briefing references this CVE

SecOps Signal surfaces public advisory facts only. A missing value means the source has not published it, not that your environment is unaffected. No tenant inventory is connected.