SecOps SignalSecurity Intelligence Workspace
Loading collection status
Vulnerabilities/CVE-2026-42566Public Intelligence Dossier
Source: meshtastic · Limited verification•Last verified: •Collection Degraded
CVE-2026-42566Unknown / EvaluatingHIGH (raw)CVSS 7.5CWE-20

Meshtastic is an open source mesh networking solution

Published: 20 Jul 2026•Last updated: 25 Oct 2026, 01:40 AM IST•Source identifier: security-advisories@github.com
Dossier completeness: source-provided sections 2 / 3 · rule guidance available. Missing source facts count as incomplete.
Official source
CISA KEV catalog
Unknown
KEV status was not determined.
CVSS score
7.5HIGH (raw)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Metric sourcesecurity-advisories@github.com
EPSS probability
0.5%0.005
Percentile42nd
Weakness type
CWE-20
No further CWE recorded
Remediation
Patch status unknown
No fixed version or KB recorded

Why It Matters

Analysis dossier

Why It Matters

Meshtastic is an open source mesh networking solution. Prior to version 2.7.23.b246bcd, a single node advertising a User.long_name that contains a malformed character encoding can render other radios unusable over BLE when managed through the iOS app. The malformed name does not need to be maliciously crafted — it can arise from ordinary buffer truncation and has been observed occurring naturally in the wild. At least one code path could place a null terminator in the middle of a multibyte sequence, leaving a malformed User.long_name in the node database. The problem surfaced downstream: the iOS app enforced encoding validation and therefore cannot parse a node database once it contains a poisoned entry. This caused BLE sync to enter a fail/retry loop, resulting in loss of control over the affected device. For a typical user managing their radio with the iOS app, the device becomes effectively unusable until the poisoned node ages out of the on-device database, or unless they have an alternate management path (e.g., the Python CLI, which can be used to identify and remove the offending entries manually). Because the malformed name propagates through the mesh, the temporary presence of a single affected node can degrade BLE management for iOS users across a wide geographical area for an extended period. Less technical users have no straightforward recovery path. Starting in version 2.7.23.b246bcd, the firmware has added input sanitization and regression tests demonstrating recovery for already-poisoned devices. The apps have also taken steps to ensure more graceful handling of malformed encoding sequences as well.

SOC priority

High

Actively exploited (source statement)

Unknown

Publicly disclosed

Unknown

Risk basis: SOC ecosystem technology relevance; HIGH severity; Source severity; no confirmed exploitation signal

Affected Products & Remediation

1 source-backed product
Affected products and versions (source)
  • meshtastic meshtastic firmware · <= 2.7.22 · NVD CPE · Source
Recorded patch / KBNot provided by source

Vendor or catalog guidance (source)

Not provided by source

Known exploitation (source facts)

Only what a source states. Unknown means no source has said either way; it is not "not exploited".

CISA KEV
Unknown
Exploited (source statement)
Unknown
Publicly disclosed (source)
Unknown

Suggested hunting (rule-based inference)

SecOps Signal recommendation (rule-based inference). These steps are hunting hypotheses from the vulnerability class; they do not state or imply that exploitation occurred here or anywhere.

Matched network-unauthenticated (CVSS AV:N, CVSS PR:N, CVSS UI:N)

Exposure

  1. Identify devices reporting this CVE and note which expose the affected service to untrusted networks.Telemetry: DeviceTvmSoftwareVulnerabilities · A network-reachable, no-privilege vector makes internet-facing instances the first exposure question. · Rule network-unauthenticated

Exploitation evidence

  1. Review inbound connections to the affected service from unexpected sources since the advisory date.Telemetry: DeviceNetworkEvents · Hunting hypothesis from the CVSS vector; it does not show that exploitation occurred. · Rule network-unauthenticated

Response

  1. Confirm the source-stated update is installed and the CVE is no longer reported.Telemetry: DeviceTvmSoftwareVulnerabilities · A follow-up inventory check verifies remediation. · Rule network-unauthenticated

CISA KEV Record

CISA KEV status was not determined for this record.

Change History & Source Data

— No recorded material change

CNA / source
security-advisories@github.com
Record status · verification
UPDATED · NVD API
CPE
cpe:2.3:o:meshtastic:meshtastic_firmware:*:*:*:*:*:*:*:*

Linked by the query's stored exact CVE association. Review required tables and validation status before use.

Detection Hunting Query
Target: DeviceTvmSoftwareVulnerabilities•Defender XDR
Detect endpoints exposed to CVE-2026-42566
Purpose: Exposure assessment (Category: Exposure Check)Why linked: Query metadata names CVE-2026-42566
DeviceTvmSoftwareVulnerabilities| where CveId == "CVE-2026-42566"| project DeviceId, DeviceName, OSPlatform, OSVersion, SoftwareVendor, SoftwareName, SoftwareVersion, CveId, VulnerabilitySeverityLevel, RecommendedSecurityUpdate, RecommendedSecurityUpdateId| sort by VulnerabilitySeverityLevel desc
Schema Checked · Not runtime validatedSource: SecOps Signal deterministic template · Limited verificationStatic screening: Passed structure and schema checks; tenant execution is not verified.

Looking up related community queries…

Loading related intelligence

Correlated briefings